Use este identificador para citar ou linkar para este item: https://biblioteca.cbm.df.gov.br/jspui/handle/123456789/586
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.advisorCavalcanti, Paulo Fernando Leal de Holanda-
dc.contributor.authorRodrigues, Leonardo Silva Júlio-
dc.date2025pt_BR
dc.date.accessioned2025-09-29T18:30:25Z-
dc.date.available2025-09-29T18:30:25Z-
dc.date.issued2025-05-06-
dc.identifier.citationRODRIGUES, Leonardo Silva Júlio. Estudo sobre a gestão dos equipamentos autônomos de proteção respiratória no CBMDF com vistas à proposição da criação de um programa de proteção respiratória para a atvidade de combate a incêndio urbano. 2025. Trabalho de Conclusão de Curso (Curso de Aperfeiçoamento de Oficiais) - Corpo de Bombeiros Militar do Distrito Federal, Brasília, 2025.pt_BR
dc.identifier.urihttps://biblioteca.cbm.df.gov.br/jspui/handle/123456789/586-
dc.descriptionTrabalho de conclusão de curso — Corpo de Bombeiros Militar do Distrito Federal, Centro de Estudos de Política, Estratégia e Doutrina, Curso de Aperfeiçoamento de Oficiais, 2025.pt_BR
dc.description.abstractO artigo estuda o gerenciamento dos Equipamentos Autônomos de Proteção Respiratória (EAPRs) no Corpo de Bombeiros Militar do Distrito Federal (CBMDF), visando a otimizar sua gestão e ciclo de vida, aumentar sua eficiência, garantir a segurança dos bombeiros e reduzir custos operacionais e logísticos na atividade de Combate a Incêndio Urbano. Trata-se de uma pesquisa aplicada, com abordagem qualitativa, exploratória e descritiva, utilizando os métodos indutivo e dedutivo. O estudo foi conduzido por meio de pesquisa bibliográfica e documental, entrevistas com gestores do CBMDF e instrutor britânico, e análise comparativa com normas e diretrizes nacionais e internacionais, como as da FUNDACENTRO, NFPA 1500 e 1852, além de documentos do Reino Unido. Os resultados indicaram avanços, como a padronização de modelos e capacitação em cursos de formação, mas também fragilidades, como a ausência de normativas sobre descarte, controle de obsolescência, manutenção preventiva e rastreabilidade. Elementos essenciais do Programa de Proteção Respiratória (PPR) ainda não são adotados, como ensaios de vedação, controle da qualidade do ar comprimido e avaliações médicas periódicas. Boas práticas internacionais, como uso de logbooks, certificação técnica e revalidações periódicas, ofereceram fundamentos robustos à proposta. Conclui-se que a criação de um PPR no CBMDF é imperativa, devendo este programa integrar gestão técnica, saúde ocupacional e capacitação continuada, preenchendo as lacunas existentes. Futuros estudos podem explorar a implementação e avaliação prática do PPR proposto.pt_BR
dc.description.abstractThis article examines the management of Self-Contained Breathing Apparatuses (SCBAs) within the Federal District Military Fire Brigade (CBMDF), aiming to optimize their management and life cycle, enhance efficiency, ensure firefighter safety, and reduce operational and logistical costs in firefighting activities. This is an applied research study with a qualitative, exploratory, and descriptive approach, using both inductive and deductive methods. The analysis involved bibliographic and documentary research, interviews with CBMDF managers and a British instructor, and a comparative review of national and international standards and guidelines, such as the Respiratory Protection Program (RPP) by FUNDACENTRO, NFPA 1500 and 1852, and documents from the United Kingdom. The results revealed progress, including equipment standardization and training integration into educational programs, but also critical gaps, such as the absence of regulations for disposal, obsolescence control, preventive maintenance, and traceability. Essential RPP elements are still missing, such as fit testing, compressed air quality control, and periodic medical evaluations. International best practices - such as individual logbooks, technical certification, and periodic revalidation - provided solid foundations for the proposed improvements. The study concludes that the implementation of an RPP in the CBMDF is essential. The program should integrate technical management, occupational health, and continuous training, addressing the identified gaps. Future research may focus on the practical implementation and assessment of the proposed RPP.en
dc.language.isopt_BRpt_BR
dc.rightsAcesso aberto a texto completopt_BR
dc.subjectDistrito Federal. Corpo de Bombeiros Militarpt_BR
dc.subjectEquipamento de proteção respiratóriapt_BR
dc.subjectEquipamento de proteção individualpt_BR
dc.subjectSaúde ocupacionalpt_BR
dc.subjectIncêndios urbanos - Combatept_BR
dc.subjectAdministração de materiaispt_BR
dc.titleEstudo sobre a gestão dos equipamentos autônomos de proteção respiratória no CBMDF com vistas à proposição da criação de um programa de proteção respiratória para a atvidade de combate a incêndio urbanopt_BR
dc.typeArticlept_BR
Aparece nas coleções:CAO 2024/2025

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
LEONARDO SILVA JÚLIO RODRIGUES.pdfTexto completo5,25 MBAdobe PDFVisualizar/Abrir
LEONARDO SILVA JÚLIO RODRIGUES-SEI_171508350_Autorizacao.pdf
  Restricted Access
Termo de autorização55,4 kBAdobe PDFVisualizar/Abrir    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.