Use este identificador para citar ou linkar para este item: https://biblioteca.cbm.df.gov.br/jspui/handle/123456789/61
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.advisorPalmeira Junior, George Lopes
dc.contributor.authorMadureira, Celso Rollemberg
dc.date2019pt_BR
dc.date.accessioned2020-01-14T18:50:11Z
dc.date.available2020-01-14T18:50:11Z
dc.date.issued2019-12-04
dc.identifier.citationMADUREIRA, Celso Rollemberg. Ferramenta de gerenciamento da descontaminação e manutenção do equipamento de proteção respiratória Scott. 2019. Trabalho de Conclusão de Curso (Curso de Formação de Oficiais) - Corpo de Bombeiros Militar do Distrito Federal, Brasília, 2019.pt_BR
dc.identifier.urihttp://biblioteca.cbm.df.gov.br/jspui/handle/123456789/61
dc.descriptionTrabalho de conclusão de curso — Corpo de Bombeiros Militar do Distrito Federal, Academia de Bombeiro Militar, Curso de Formação de Oficiais, 2019.pt_BR
dc.description.abstractEste trabalho analisa os procedimentos de descontaminação e manutenção dos Equipamentos de Proteção Respiratória (EPRs), da marca SCOTT, no âmbito do Corpo de Bombeiros Militar do Distrito Federal (CBMDF). Tal abordagem se justifica, primeiramente, pela classificação no grupo 2B dada pela Agência Internacional de Pesquisa em Câncer (AIPC) à profissão bombeiro militar, sendo uma ocupação possivelmente cancerígena e, em segundo plano, pelo número significativo de equipamentos que apresentam defeitos e se encontram baixados, sem condições de uso. O objetivo deste trabalho é averiguar a aplicabilidade do atual modelo de gestão da descontaminação e manutenção dos EPRs SCOTT, adotado nas unidades operacionais (GBMs) e na Seção de Manutenção de Equipamentos (SEMAE) do Centro de Manutenção de Equipamentos e Viaturas (CEMEV). Este propósito foi conseguido mediante estudos sobre a exposição do bombeiro militar a contaminantes durante o combate a incêndios, as formas de descontaminação dos equipamentos, as normas internacionais que regem a qualidade do ar e a inspeção dos EPRs, os componentes do equipamento, sua operação e testes, além da visita à SEMAE e aos GBMs para analisar a gestão dos EPRs na corporação. Os estudos e a pesquisa demonstraram que os procedimentos de descontaminação, inspeção, higienização, testes de funcionamento, apesar de serem conhecidos, são incipientes, pois ainda não há uma padronização; gerando exposição demasiada a contaminantes e problemas nos equipamentos. É necessário, portanto, conceber o ciclo do EPR, criando, para tal, uma ferramenta de gerenciamento da descontaminação e manutenção dos EPRs, em que os procedimentos sejam padronizados, todos tenham acesso à plataforma digital e responsabilidade sobre os equipamentos. Visando difundir uma cultura de descontaminação e manutenção, aumentando a expectativa de vida do bombeiro e a vida útil dos equipamentos.pt_BR
dc.description.abstractThis paper analyzes the decontamination and maintenance procedures of Scott Air-Pak within the Federal District Fire Department. Firstly, this approach is justified by the Group 2B classification given by the International Agency Research on Cancer, IARC, to the firefighter job, being a potentially carcinogenic occupation, and, secondly, by the significant number of broken air-paks, without conditions of use. The goal is to analyses the current model of air-pak’s decontamination and maintenance, adopted in fire stations and in the maintenance section, regarding the firefighter health and preventive maintenance. This goal will be based on studies of firefighter exposure to contaminants during fire combat and decontamination methods, of international standings about the air-pak inspection and air quality, on air-pak components, their operation and testing, on a visit to the maintenance section and fire stations to understand the current air-pak’s management tool applied. Decontamination, inspection, cleaning and functional testing, although known, are incipient in the fire department. Yet there are not standard procedures, what cause excessive exposure to contaminants and air-pak functional problems. Therefore, it is necessary to develop a management tool of air-pak decontamination and maintenance, in which there will be standard procedures, with free access to a digital platform and responsibilities. Aiming to spread a decontamination and maintenance culture, increasing life expectancy of firefighters and a long life to the air-pak.en
dc.language.isopt_BRpt_BR
dc.rightsAcesso aberto a texto completopt_BR
dc.subjectEquipamento de proteção respiratóriapt_BR
dc.subjectContaminação de equipamentospt_BR
dc.subjectEquipamento de proteção individualpt_BR
dc.subjectCombate a incêndios - Proteçãopt_BR
dc.subjectDistrito Federal. Corpo de Bombeiros Militarpt_BR
dc.titleFerramenta de gerenciamento da descontaminação e manutenção do equipamento de proteção respiratória Scottpt_BR
dc.title.alternativeManagement tool of Scott air-pak decontamination and maintenanceen
dc.typeArticlept_BR
Aparece nas coleções:CFO 35

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1072 - Artigo - Rollemberg.pdfArtigo científico801,68 kBAdobe PDFVisualizar/Abrir
1072 - Manual - Rollemberg - pdfa.pdfAnexo - Manual para utilização do site555,89 kBAdobe PDFVisualizar/Abrir
SEI_GDF - 32135035 - Autorização.pdf
  Restricted Access
Termo de autorização91,12 kBAdobe PDFVisualizar/Abrir    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.